Single Output Industrial DIN Rail Power Supply (30W) - 12V/2A

by Mean Well

This is an economical ultra slim 30W DIN rail power supply, designed to be installed on TS-35/7.5 or TS-35/15 mounting rails.

Features

  • ultra slim design with 35 mm (2SU) width
  • universal input 85-264 VAC (277 VAC operational)
  • no load power consumption <0.3 W
  • isolation class II
  • pass LPS (limited power source)
  • DC output voltage adjustable
  • protections: short circuit / overload / over voltage
  • cooling by free air convection (working temperature : -30 - +70°C)
  • DIN rail TS-35/7.5 or 15 mountable
  • over voltage category III
  • LED indicator power on
  • 3 year warranty
  • for professional use only
  • This device must be installed by a qualified person.

Specifications

  • output:
    • DC voltage: 12 V
    • rated current: 2 A
    • current range: 0 - 2 A
    • rated power: 24 W
    • ripple & noise (max.): 120 mVp-p
    • voltage adj. range: 10.8 - 13.8 V
    • voltage tolerance: ± 1.0 %
    • line regulation: ± 1.0 %
    • load regulation: ± 1.0 %
    • setup, rise time: 500 ms, 50 ms / 230 VAC - 500 ms, 50 ms / 115 VAC at full load
    • hold up time (typ.): 30 ms / 230 VAC - 12 ms / 115 VAC at full load
  • input:
    • voltage range: 85-264 VAC (277 VAC operational) - 120-370 VDC (390 VDC operational)
    • frequency range: 47 - 63 Hz
    • efficiency (typ.): 88 %
    • ac current (typ.): 0.88 A / 115 VAC - 0.48 A / 230 VAC
    • inrush current (typ.): cold start 25 A / 115 VAC - 45 A / 230 VAC
  • protection:
    • overload:
      • 105 - 160 % rated output power
      • protection type: constant current limiting, recovers automatically after fault condition is removed
    • overvoltage:
      • 15 - 18 V
      • protection type: shut down output voltage, re-power on to recover
  • environment:
    • working temperature: -30 to +70 °C
    • working humidity: 20 to 90 % RH non-condensing
    • storage: -40 to +85 °C, 10 to 95% RH
    • temperature coefficient: ± 0.03 %/°C (0 - 50°C )
    • vibration: 10 - 500 Hz, 2G 10 min / 1 cycle, 60 min each along X, Y, Z axes; mounting: compliance to IEC60068-2-6
    • operating altitude: 2000 m
    • over voltage category: III, according to EN61558, EN50178, EN60664-1, EN62477-1, altitude up to 2000 meters
  • safety & EMC:
    • safety standards: UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved, design refer to TUV EN60950-1
    • withstand voltage: input to output: 4 kVAC
    • isolation resistance: input to output: 100 MOhm / 500 VDC / 25 °C / 70 % RH
    • EMC emission:
      • conducted: EN55032 (CISPR32) / Class B
      • radiated: EN55032 (CISPR32) / Class B
      • harmonic current: EN61000-3-2 / Class A
      • voltage flicker: EN61000-3-3
    • EMC immunity:
      • ESD: EN61000-4-2 / Level 3, 8KV air - Level 2, 4KV contact - criteria A
      • radiated susceptibility: EN61000-4-3 / Level 3 - criteria A
      • EFT/Burest: EN61000-4-4 / Level 3 - criteria A
      • surge: EN61000-4-5 / Level 4, 2KV/L-N - criteria A
      • conducted: EN61000-4-6 / Level 3 - criteria A
      • magnetic field: EN61000-4-8 / Level 4, criteria A
      • voltage dips and interruptions: EN61000-4-11 / >95% dip 0.5 periods, 30% dip 25 periods - >95% interruptions 250 periods
  • other:
    • MTBF: 968.1Kh, MIL-HDBK-217F (25 °C)
    • dimensions: 35 x 90 x 54.5 mm (w x h x d)

Documents