{"product_id":"industrial-din-rail-power-supply-single-output-60w","title":"Single Output Industrial DIN Rail Power Supply (60W)","description":"\u003cp\u003eThis is an economical ultra slim 60W DIN rail power supply, designed to be installed on TS-35\/7.5 or TS-35\/15 mounting rails.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eultra slim design with 52.5 mm (3SU) width\u003c\/li\u003e\n\u003cli\u003euniversal input 85-264 VAC (277 VAC operational)\u003c\/li\u003e\n\u003cli\u003eno load power consumption \u0026lt;0.3 W\u003c\/li\u003e\n\u003cli\u003eisolation class II\u003c\/li\u003e\n\u003cli\u003epass LPS (limited power source)\u003c\/li\u003e\n\u003cli\u003eDC output voltage adjustable\u003c\/li\u003e\n\u003cli\u003eprotections: short circuit \/ overload \/ over voltage\u003c\/li\u003e\n\u003cli\u003ecooling by free air convection (working temperature : -30 - +70°C)\u003c\/li\u003e\n\u003cli\u003eDIN rail TS-35\/7.5 or 15 mountable\u003c\/li\u003e\n\u003cli\u003eover voltage category III\u003c\/li\u003e\n\u003cli\u003eLED indicator power on\u003c\/li\u003e\n\u003cli\u003e3 year warranty\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003efor professional use only\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003eThis device must be installed by a qualified person.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eOutput\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e12 V - 4.5 A\u003c\/td\u003e\n\u003ctd\u003e24 V - 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e12 v\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003erated current\u003c\/td\u003e\n\u003ctd\u003e4.5 A\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecurrent range\u003c\/td\u003e\n\u003ctd\u003e0 - 4.5 A\u003c\/td\u003e\n\u003ctd\u003e0 - 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003erated power\u003c\/td\u003e\n\u003ctd\u003e54 W\u003c\/td\u003e\n\u003ctd\u003e60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eripple \u0026amp; noise (max.)\u003c\/td\u003e\n\u003ctd\u003e120 mVp-p\u003c\/td\u003e\n\u003ctd\u003e150 mVp-p\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evoltage adj. range\u003c\/td\u003e\n\u003ctd\u003e10.8 - 13.8 V\u003c\/td\u003e\n\u003ctd\u003e21.6 - 29 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003evoltage tolerance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eline regulation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eload regulation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esetup, rise time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 ms, 50 ms \/ 230 VAC - 500 ms, 50 ms \/ 115 VAC at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehold up time (typ.)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 ms \/ 230 VAC - 12 ms \/ 115 VAC at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003einput:\n\u003cul\u003e\n\u003cli\u003evoltage range: 85-264 VAC (277 VAC operational) - 120-370 VDC (390 VDC operational)\u003c\/li\u003e\n\u003cli\u003efrequency range: 47 - 63 Hz\u003c\/li\u003e\n\u003cli\u003eefficiency (typ.): 90 % (24V) \/ 88% (12V)\u003c\/li\u003e\n\u003cli\u003eac current (typ.): 1.2 A \/ 115 VAC - 0.8 A \/ 230 VAC\u003c\/li\u003e\n\u003cli\u003einrush current (typ.): cold start 30 A \/ 115 VAC - 60 A \/ 230 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eprotection:\n\u003cul\u003e\n\u003cli\u003eoverload:\n\u003cul\u003e\n\u003cli\u003e105 - 160 % rated output power\u003c\/li\u003e\n\u003cli\u003eprotection type: constant current limiting, recovers automatically after fault condition is removed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eovervoltage:\n\u003cul\u003e\n\u003cli\u003e30 - 36 V (24V) \/ \u003cspan\u003e14.2 - 16.2 V (12V)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eprotection type: shut down output voltage, re-power on to recover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eenvironment:\n\u003cul\u003e\n\u003cli\u003eworking temperature: -30 to +70 °C\u003c\/li\u003e\n\u003cli\u003eworking humidity: 20 to 90 % RH non-condensing\u003c\/li\u003e\n\u003cli\u003estorage: -40 to +85 °C, 10 to 95% RH\u003c\/li\u003e\n\u003cli\u003etemperature coefficient: ± 0.03 %\/°C (0 - 50°C )\u003c\/li\u003e\n\u003cli\u003evibration: 10 - 500 Hz, 2G 10 min \/ 1 cycle, 60 min each along X, Y, Z axes; mounting: compliance to IEC60068-2-6\u003c\/li\u003e\n\u003cli\u003eoperating altitude: 2000 m\u003c\/li\u003e\n\u003cli\u003eover voltage category: III, according to EN61558, EN50178, EN60664-1, EN62477-1, altitude up to 2000 meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003esafety \u0026amp; EMC:\n\u003cul\u003e\n\u003cli\u003esafety standards: UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved, design refer to TUV EN60950-1\u003c\/li\u003e\n\u003cli\u003ewithstand voltage: input to output: 4 kVAC\u003c\/li\u003e\n\u003cli\u003eisolation resistance: input to output: 100 MOhm \/ 500 VDC \/ 25 °C \/ 70 % RH\u003c\/li\u003e\n\u003cli\u003eEMC emission:\n\u003cul\u003e\n\u003cli\u003econducted: EN55032 (CISPR32) \/ Class B\u003c\/li\u003e\n\u003cli\u003eradiated: EN55032 (CISPR32) \/ Class B\u003c\/li\u003e\n\u003cli\u003eharmonic current: EN61000-3-2 \/ Class A\u003c\/li\u003e\n\u003cli\u003evoltage flicker: EN61000-3-3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEMC immunity:\n\u003cul\u003e\n\u003cli\u003eESD: EN61000-4-2 \/ Level 3, 8KV air - Level 2, 4KV contact - criteria A\u003c\/li\u003e\n\u003cli\u003eradiated susceptibility: EN61000-4-3 \/ Level 3 - criteria A\u003c\/li\u003e\n\u003cli\u003eEFT\/Burest: EN61000-4-4 \/ Level 3 - criteria A\u003c\/li\u003e\n\u003cli\u003esurge: EN61000-4-5 \/ Level 4, 2KV\/L-N - criteria A\u003c\/li\u003e\n\u003cli\u003econducted: EN61000-4-6 \/ Level 3 - criteria A\u003c\/li\u003e\n\u003cli\u003emagnetic field: EN61000-4-8 \/ Level 4, criteria A\u003c\/li\u003e\n\u003cli\u003evoltage dips and interruptions: EN61000-4-11 \/ \u0026gt;95% dip 0.5 periods, 30% dip 25 periods - \u0026gt;95% interruptions 250 periods\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eother:\n\u003cul\u003e\n\u003cli\u003eMTBF: 927.6Kh, MIL-HDBK-217F (25 °C)\u003c\/li\u003e\n\u003cli\u003edimensions: 52.5 x 90 x 54.5 mm (w x h x d)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0174\/1800\/files\/hdr-60_infosheet.pdf?v=1589196981\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0174\/1800\/files\/powersupplya4v04.pdf?v=1589196981\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eGeneral Safety information\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mean Well","offers":[{"title":"24V\/2.5A","offer_id":31759309471827,"sku":"HDR-60-24","price":23.95,"currency_code":"EUR","in_stock":false},{"title":"12V\/4.5A","offer_id":31759309504595,"sku":"HDR-60-12","price":23.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0174\/1800\/products\/hdr-60.jpg?v=1591183762","url":"https:\/\/shop.pimoroni.com\/en-eu\/products\/industrial-din-rail-power-supply-single-output-60w","provider":"Pimoroni Ltd","version":"1.0","type":"link"}